Thickness Gauge HTG modular
The following measuring stands we deliver without weight/without foot:
Model
|
Order.-No.
|
Description
|
Download
|
Weight
(Kg) |
---|---|---|---|---|
HTG |
219 200-V |
Measuring Stand with extention arm without digital dial gauge |
Drawing |
6,0 |
HTG-A |
219 201-V |
Measuring Stand with extention arm and digital dial gauge 1075R |
Drawing |
6,2 |
HTG-B |
219 202-1-V |
Measuring Stand with extention arm and digital dial gauge Dial NanoS (12,5 mm) |
Drawing |
6,2 |
HTG-B-L |
219 202-1-L-V |
Measuring Stand with extention arm and digital dial gauge Dial NanoS (25 mm) |
Drawing |
6,2 |
HTG-C |
219 204-V |
Measuring Stand with extention arm incl. manual lever and digital gauge 1075R |
Drawing |
7,0 |
Do you have any questions? We will be happy to advise you personally: Contact form
+49 7024 8099872
The following weights and foots can be used as a upgrade for HTG-A, HTG-1, HTG-3, HTG-4, HTG-5, HTG-11, HTG-12, HTG-13, HTG-14, HTG-15, HTG-16, HTG-18:
Order.-No.
|
Standard
|
Application
|
Foot Ø
(mm) |
Weight
(g) |
Pressure
(kPa) |
---|---|---|---|---|---|
219 3021 |
ISO 23529 ASTM D 3767 |
Rubber |
5,0 |
20,0 |
10,0 |
219 302 |
ISO 23529 ASTM D 3767 |
Rubber |
6,0 |
29,0 |
10,0 |
219 306 |
ASTM D 3767 |
Rubber |
6,3 |
32,0 |
10,0 |
219 3022 |
ISO 23529 ASTM D 3767 |
Rubber |
8,0 |
51,0 |
10,0 |
219 3023 |
ISO 23529 ASTM D 3767 |
Rubber |
10,0 |
80,0 |
10,0 |
219 305 |
ASTM D 3767 |
Rubber |
16,0 |
212,0 |
10,0 |
219 3011 |
ISO 23529 |
Rubber |
3,0 |
16,0 |
22,0 |
219 3016 |
ASTM D 3767 |
Rubber |
3,2 |
18,0 |
22,0 |
219 301 |
ISO 23529 ASTM D 3767 |
Rubber |
4,0 |
28,0 |
22,0 |
219 3012 |
ISO 23529 ASTM D 3767 |
Rubber |
5,0 |
44,0 |
22,0 |
219 3013 |
ISO 23529 ASTM D 3767 |
Rubber |
6,0 |
63,0 |
22,0 |
219 3051 |
ASTM D 3767 |
Rubber |
6,3 |
70,0 |
22,0 |
219 314 |
ISO 23529 ASTM D 3767 |
Rubber |
8,0 |
113,0 |
22,0 |
219 315 |
ISO 23529 ASTM D 3767 |
Rubber |
10,0 |
176,0 |
22,0 |
219 303 |
ISO 5084 |
Textiles |
50,5 |
204,0 |
1,0 |
219 307 |
ASTM D 1777 Option 2 |
Textile Materials, coated fabrics, Webbings, Tapes, Ribbons, Braids |
9,5 |
169,0 |
23,4 |
219 320 |
ASTM D 1777 Option 5 |
Blankets, pile fabrics, napped fabrics |
28,7 |
46,2 |
0,7 |
219 308 |
ISO 9073-2 Method A |
Nonwoven |
56,4 |
128,6 |
0,5 |
219 309 |
DIN EN ISO 1849-2 |
Flexible sheets for waterproofing |
10,0 |
160,0 |
20,0 |
219 310 219 086 |
DIN EN ISO 24346 part 2 |
Resilient floor coverings Horseshoe 500 g |
25,3 |
200,0 |
4,0 |
219 3012 |
DIN EN ISO 12625-3 |
Tissue |
35,7 |
204,0 |
2,0 |
219 313 |
DIN EN ISO 2286-3 Teil 3 |
Rubber- or plastics-coated fabrics |
10,0 |
16,0 |
2,0 |
219 3131 |
DIN EN ISO 2286-3 Teil 3 |
Rubber- or plastics-coated fabrics |
10,0 |
40,0 |
5,0 |
219 3132 |
DIN EN ISO 2286-3 Teil 3 |
Rubber- or plastics-coated fabrics |
10,0 |
80,0 |
10,0 |
219 3133 |
DIN EN ISO 2286-3 Teil 3 |
Rubber- or plastics-coated fabrics |
10,0 |
80,0 |
10,0 |
219 319 |
ASTM D 1777 Option 1 |
Woven fabrics, knitted fabrics, textured fabrics |
28,7 |
273,0 |
4,14 |
219 323 |
ASTM F 2251 |
Flexible packaging material |
6,35 |
10...150 |
--- |
The following weights and foots can be used as a upgrade for HTG-C, HTG-6, HTG-7, HTG-8, HTG-9, HTG-10, HTG-17:
Order.-No.
|
Standard
|
Application
|
Foot Ø
(mm) |
Weight
(g) |
Pressure
(kPa) |
---|---|---|---|---|---|
219 315 |
DIN EN ISO 2589 |
Leather |
10,0 |
393,0 |
49,1 |
219 316 |
ASTM D 1777 Option 3 |
Films, Glass cloths, Glass tapes |
6,3 |
546,7 |
172,0 |
219 311 |
ASTM D 5199 |
Geosynthetics |
56,4 |
509,5 |
2,0 |
219 317 |
DIN EN ISO 534 |
Paper and Cardboard |
16,0 |
2050,0 |
100,0 |
219 318 |
DIN EN ISO 3034 |
Cardboard |
35,7 |
2041,0 |
20,0 |
219 321 |
ASTM F 2251 |
Flexible packaging material |
15,875 |
1033,0 |
50,3 |
The stated weight is the total mass (foot + weight + measuring spindle).
For your special requirements you can order the measuring stands separately or you can combine it with additionals weights/feets. Please send us your requirements. We will help you to select the proper components (Inquiry).
The constant force enables repeatable readings.
We use only corrosion-resistant materials. Therefore you can use the Hildebrand thickness gauges in environments with high humidity.
Features measuring stands:
- Laboratory grade granite base: Ø200 mm x 40 mm
- Column diameter: 30 mm (stainless steel)
- Sturdy extention arm (HTG-A und HTG-B steinless steel; HTG-C aluminium)
- Individuelle Seriennummer auf dem Gewicht/Messfuß eingraviert
- Ball bearings enables low friction (HTG-C)
- Weight: approx. 5 - 8 Kg
Features weight/foot:
- Weight according to model consists of stainless steel or aluminium
- Foot according to model consists of stainless steel or aluminium
Features digital dial gauge:
- Digital dial gauge 1075R:
- You can measure material thickness up to 12 mm. Above 12 mm you require a slip gauge (accessories) and the Preset-Function of the electronic gauge (e.g. 10 mm slip block: Material thickness 10 up to 22 mm).
- Resolution: 0,001 mm
- Digital dial gauge Dial NanoS:
- Measuring way: 12,5 mm (HTG-B)
- Measuring way: 25,0 mm (HTG-B-L)
- 3 Resolution selectable: (HTG-B):
- Resolution 10 μm = max. error 10 μm
- Resolution 1 μm = max. error 3 μm
- Resolution 0.1 μm = max. error 1.8 μm
- 3 Resolution selectable: (HTG-B-L):
- Resolution 10 μm = max. error 10 μm
- Resolution 1 μm = max. error 4 μm
- Resolution 0.1 μm = max. error 2.2 μm
- Thickness Gauge
- Cable lifting device (HTG-B-L, HTG-A Messgewicht <149 g)
- Lifting device (HTG-B, HTG-A measuring weight >150 bis 290 g)
- Custom made carrying case (HTG-A und HTG-B, HTG-B-L)
- Operating instructions
Optional:
- Calibration certificate issued by Hildebrand Prüf- und Meßtechnik GmbH
- DAkkS calibration for Dial gauge